The CAN bus is a broadcast type of bus. This means that all nodes can "hear"
all transmissions. There is no way to send a message to just a specific node; all nodes
will invariably pick up all traffic. The CAN hardware, however, provides local filtering
so that each node may react only on the interesting messages.
The CAN messages
CAN uses short messages - the maximum utility
load is 94 bits. There is no explicit address in
the messages; instead, the messages can be said
to be contents-addressed, that is, their
contents implicitly determines their address.
|
Message Types
There are four different message types (or
"frames") on a CAN bus:
- the Data Frame,
- the Remote Frame,
- the Error Frame, and
- the Overload Frame.
|
The Data Frame
Summary: "Hello
everyone, here's some data labeled X, hope you
like it!"
The Data Frame is
the most common message type. It comprises the
following major parts (a few details are omitted
for the sake of brevity):
- the Arbitration Field, which determines
the priority of the message when two or
more nodes are contending for the bus.
The Arbitration Field contains:
- For CAN 2.0A, an 11-bit
Identifier and one bit, the RTR
bit, which is dominant for data
frames.
- For CAN 2.0B, a 29-bit Identifier
(which also contains two
recessive bits: SRR and IDE) and
the RTR bit.
- the Data Field, which contains zero to
eight bytes of data.
- the CRC Field, which contains a 15-bit
checksum calculated on most parts of the
message. This checksum is used for error
detection.
- an Acknowledgement Slot; any CAN
controller that has been able to
correctly receive the message sends an
Acknowledgement bit at the end of each
message. The transmitter checks for the
presence of the Acknowledge bit and
retransmits the message if no acknowledge
was detected.
Note 1: It is worth noting that the presence
of an Acknowledgement Bit on the bus does not
mean that any of the intended addressees
has received the message. The only thing we know
is that one or more nodes on the bus has
received it correctly.
Note 2: The Identifier in the Arbitration
Field is not, despite of its name, necessarily
identifying the contents of the message.
|

A CAN 2.0A ("standard CAN") Data Frame.

A CAN 2.0B ("extended CAN") Data Frame.
|
|