Error 3014 from the CANalyzer

When using CANalyzer V2.0d or later together with the LAPcan, the following error might occur (it is displayed in a dialog box) when a mesaurement is started:

Error 3014

The measurement is then aborted.

 

Cause:

Usually a version mismatch in the driver routines. To check this, go to the Control Panel and double-click in "CAN Hardware". On the "Diagnostic" tab, you should see text similar to

VCANCARD V2.0
VCAND V1.0 DB

The number after VCANCARD and VCAND is the driver interface version. The latest version of the interface is version 2. If the interface version numbers differ, then you have a version conflict.

To correct the problem, reinstall or upgrade the driver routines.

 