Support Note |
|||||||
ProblemHow to update KVASER hardware via the CAN-bus using WinTransfer! |
|||||||
Answer
1. Download the latest FIRMWARE package for your hardware and un-zip it to a directory on your hard disk. 2. Ask support@kvaser.com to send you the WinTransfer program. 3. Unzip the WinTransfer-package (to, for example C:\KVASER\Wintrasfer\) and type, at the command prompt: C:\KVASER\Wintransfer\wintransfer.exe -e 4. Connect the CAN hardware as described by figure below:
5. More details how to connect the CAN-bus between the devices.
6. Start up the Wintransfer program and set up as (File type, Binary area, and the address (0c0000)).
7. Browse to the IMG-file for the specific hardware.
8. POWER DOWN the CAN hardware (If it is a USB-device just unplug it, if it is a PCIcan II shut down the computer). 9. When this is done click
"Break" in the WinTransfer application. A timeout will start
ticking.
10. Click download and the transfer will start, it looks like this.
11. The download looks like this. It should take approximately 1 minute.
12. When the download is finished, please reboot the CAN hardware.
|
|||||||
|
|
|||||||